Linear Heat Detection Cable LHD

Order Code

Model

Name

Description

100201

MS1000

Linear Heat Cable

Indoor using, Alarm Threshold of 68℃, Price based on unit of meter.

100202

MS1000

Linear Heat Cable

Indoor using, Alarm Threshold  of 88℃, Price based on unit of meter.

100203

MS1000

Linear Heat Cable

Indoor using, Alarm Threshold of 105 ℃, Price based on unit of meter.

100204

MS1000

Linear Heat Cable

Indoor using, Alarm Threshold of 138℃, Price based on unit of meter.

100205

MS1000

Linear Heat Cable

Indoor using, Alarm Threshold of 180℃, Price based on unit of meter.



Order Code

Model

Name

Description

100301

MS1000-CR

Linear Heat Cable

High Performance of Chemical Resistance,
               Alarm Threshold of 68℃ , Price based on unit of meter.

100302

MS1000-CR

Linear Heat Cable

High Performance of Chemical Resistance,
               Alarm Threshold of 88℃, Price based on unit of meter.

100303

MS1000-CR

Linear Heat Cable

High Performance of Chemical Resistance,
               Alarm Threshold of 105 ℃, Price based on unit of meter.

100304

MS1000-CR

Linear Heat Cable

High Performance of Chemical Resistance,
               Alarm Threshold of 138 ℃, Price based on unit of meter.

100305

MS1000-CR

Linear Heat Cable

High Performance of Chemical Resistance,
               Alarm Threshold of 180 ℃,Price based on unit of meter.


Order Code

Model

Name

Description

100401

MS1000-OD

Linear Heat Cable

Outdoor using, Weather proof,
               Alarm Threshold of 68℃. Price based on unit of meter.

100402

MS1000-OD

Linear Heat Cable

Outdoor using, Weather proof,
               Alarm Threshold of 88℃. Price based on unit of meter.

100403

MS1000-OD

Linear Heat Cable

Outdoor using, Weather proof,
             Alarm Threshold of 105 ℃. Price based on unit of meter.

100404

MS1000-OD

Linear Heat Cable

Outdoor using, Weather proof,
               Alarm Threshold of 138℃. Price based on unit of meter.

100405

MS1000-OD

Linear Heat Cable

Outdoor using, Weather proof,
               Alarm Threshold of 180℃. Price based on unit of meter.


Order Code

Model

Name

Description

100501

MS1000-EP

Linear Heat Cable

Explosion Proof, Used in Hazardous Areas,
               Alarm Threshold of 68℃, ExibIICT6. Price based on unit of meter.

100501

MS1000-EP

Linear Heat Cable

Explosion Proof, Used in Hazardous Areas,
               Alarm Threshold of 88℃, ExibIICT6. Price based on unit of meter.

100501

MS1000-EP

Linear Heat Cable

Explosion Proof, Used in Hazardous Areas,
               Alarm Threshold of 105 ℃, ExibIICT6. Price based on unit of meter.

100502

MS1000-EP

Linear Heat Cable

Explosion Proof, Used in Hazardous Areas,
               Alarm Threshold of 138 ℃, ExibIICT6. Price based on unit of meter.

100503

MS1000-EP

Linear Heat Cable

Explosion Proof, Used in Hazardous Areas,
               Alarm Threshold of 180 ℃, ExibIICT6. Price based on unit of meter.


Control Unit and EOL Box

MS1000-I
Linear Detector Interface


●Interface for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable
●With local fire and fault indication
●Fire and fault relay output available
●Low-power design
●Metal case

Technical Specifications
●Operating Voltage:24VDC
Operating Voltage Range: 16VDC-28VDC
●Operating Current: Standby Current:≤20mA
Fire Current:≤30mA
Fault Current:≤25mA
●Operating environment: Temperature:-55℃-60℃
Relative humidity:95%
●IP Rating :Ip66
●Dimensions:90mm × 85mm × 52mm(L×W×H)

Control Unit and EOL Box

MS1000-P 
End of Line Unit


●End of Line Unit for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable
●The functions are balancing the signal status
●For Digital linear heat cable monitoring and alarm/fault simulating

Technical Specifications
●Operating Voltage: No Electronics
●Operating environment: Temperature:-55℃-60℃
Relative humidity:95%
●IP Rating :IP66
●Dimensions:90mm×85mm×52mm(L×W×H)